CONFOCAL MICROSCOPES

A64.0960

A64.0960 Motorized Laser Confocal Scanning Microscope

A64.0960 Motorized Laser Confocal Scanning Microscope is listed with an inverted fluorescence-microscope platform and four laser wavelengths: 405nm, 488nm, 561nm, and 640nm. Its description includes a three-PMT standard arrangement and an optional GaAsP PMT configuration.

Frame the inquiry around the signals, specimen vessels, and acquisition sequence you need. OPTOEDU can discuss the listed model with those requirements and identify the selected lasers, detectors, microscope optics, software, and workstation in a quotation.

Request an A64.0960 Configuration

Explore confocal microscopes

Match detection and acquisition to the sample

The laser-light section gives a power value for each listed line. The probe-unit section distinguishes the standard PMT arrangement from the GaAsP option. Ask which detector is proposed for each signal and have the detection bands and selected options written into the configuration sheet.

The software description covers single-channel and multichannel XY imaging, XYZ stacks, XYZT acquisition, and multisite scanning. It also lists region-of-interest operations, image stitching, scale correction, filtering, and recording. Identify which functions you need and request the file-output and software-version details.

The microscope section describes a motorized inverted fluorescence platform with infinity-plan SUPER APO objectives. Ask which objectives are supplied, their working distances and immersion requirements, and how they fit the intended vessel and specimen geometry.

A64.0960 microscope controls and motorized component views
A64.0960 microscope controls and motorized component views
A64.0960 published confocal acquisition software interface
A64.0960 published confocal acquisition software interface

Published configuration information

Item Published specification or configuration
Laser line 405nm / 50mW
Laser line 488nm / 50mW
Laser line 561nm / 50mW
Laser line 640nm / 40mW
Standard detection Three PMTs listed
Detection option GaAsP PMT listed as optional
Scan zoom 1x–16x listed
Image bit depth 16-bit listed
Microscope type Motorized inverted fluorescence microscope

Confirm the laser and detector options, objectives, software, and computer package supplied with the quoted system.

Make the configuration review specific

List the fluorophores or other signals, the sample vessel, and the region to be imaged. Include any need for repeated positions, a Z series, or time-dependent observation. Request the relevant detector bands and acquisition controls for that sequence.

If environmental control is required, describe it as a separate specification request. Ask which compatible modules, stage inserts, and connections are offered rather than assuming they are included with the base system. Define the images and data your laboratory needs to export.

The page lists a computer, 4K monitor, digital camera, and professional 3D software as a package description. Ask for their current specifications and license details as separate items. Include quantity, destination, and any required evaluation procedure when requesting commercial terms.

Review the model in context

Browse the confocal microscope category and review A64.1010 for another configuration. Compare the supplied laser lines, detector choices, optics, and acquisition functions on each model’s own specification sheet.

A64.0960 questions

Which wavelengths are listed for A64.0960?

The laser-light section lists 405nm, 488nm, 561nm, and 640nm. Ask for the offered detection bands and selected power settings alongside the laser list so the configuration can be checked against your signals.

Is GaAsP detection included as standard?

The source identifies a three-PMT standard arrangement and marks GaAsP PMT as optional. Ask which channels use the proposed detector and have that choice shown in the quotation.

Which acquisition sequences are described?

The software section lists XY, XYZ, XYZT, and multisite scanning, together with several processing and recording functions. State the sequence and export requirements you need, then request the current software and workstation configuration.

Discuss the A64.0960 configuration

Send the model number and the specification requirements for your project. Ask OPTOEDU for an itemized configuration.

Reference: published A64.0960 product description.